ECAL-BOOST is a research project on the integration, testing and optimization of the homogeneous electromagnetic calorimeter (ECAL) of the Compact Muon Solenoid (CMS) experiment at CERN’s Large Hadron Collider (LHC), in preparation for the High-Luminosity LHC (HL-LHC).
Project summary
The Electromagnetic Calorimeter (ECAL) of the Compact Muon Solenoid (CMS) at CERN’s Large Hadron Collider (LHC) consists of 75,848 lead tungstate (PbWO4) crystals, designed for high-precision energy measurements. With the LHC transitioning to the High-Luminosity phase (HL-LHC), the instantaneous luminosity will increase, and the number of concurrent proton–proton collisions per bunch crossing will rise from 60 to a maximum of 200. To manage the increased event complexity and higher radiation levels, the ECAL front-end and off-detector electronics must be upgraded.
The new pre-amplifier will mitigate the radiation-induced increase in Avalanche Photodiode (APD) leakage current, while an ADC with 160 MHz oversampling will transmit data in streaming mode to the off-detector electronics with lossless data compression. This upgrade will counteract calorimeter aging while maintaining excellent energy resolution and introducing precision timing capabilities, which can be utilized for pileup mitigation and precise Higgs boson vertex localization in its two-photon decay channel.
According to the current schedule, the ECAL supermodules (SM) will be removed from the CMS detector in early 2027 and reinserted in early 2028. The 2025–2026 plan includes work on test Supermodule 36 as training for the replacement of electronics. Additionally, the development of Data Acquisition (DAQ) software modules will begin, alongside software modules for testing various electronic subsystems, including trigger towers and modules. The quality of the collected test data must be thoroughly verified, requiring the development of Data Quality Monitoring (DQM) software. Key tasks will include measuring crystal transparency, pedestal measurements, and other diagnostic processes.
In the final phase, the focus will shift to development and optimization of the spike-killer algorithm to reject signals from direct ionization of APDs by hadrons, supporting electronics integration, and commissioning.
Keywords: electronics upgrade, DAQ testing, DQM validation, L1 trigger analysis, spike-killer optimization
The detector
The CMS ECAL consists of 75,848 lead tungstate (PbWO4) crystals designed for high-precision energy measurements of electrons and photons.
Why an upgrade is needed
With the transition to the HL-LHC, the instantaneous luminosity will increase and the number of concurrent proton–proton collisions per bunch crossing will rise from about 60 to a maximum of 200. To cope with the more complex events and the higher radiation levels, the ECAL front-end and off-detector electronics must be replaced.
The new electronics
- A new pre-amplifier that mitigates the radiation-induced increase in the leakage current of the avalanche photodiodes (APDs).
- An ADC with 160 MHz oversampling that sends data in streaming mode to the off-detector electronics, using lossless data compression.
- Precision timing capabilities, which can be used for pileup mitigation and for precise localization of the Higgs boson vertex in its two-photon decay channel.
Together, these changes counteract calorimeter aging while maintaining the excellent energy resolution of the ECAL.
What the project does
- Electronics upgrade: work on test Supermodule 36 as training for the replacement of the electronics, followed by support for electronics integration and commissioning.
- DAQ testing: development of data acquisition (DAQ) software modules and of software for testing the electronic subsystems, including trigger towers and modules.
- DQM validation: development of data quality monitoring (DQM) software to verify the quality of the collected test data.
- Diagnostics: measurements of crystal transparency, pedestals and other diagnostic quantities.
- Spike-killer optimization: development and optimization of the algorithm that rejects signals caused by direct ionization of the APDs by hadrons, including L1 trigger analysis.
Timeline
| Period | Activity |
|---|---|
| 2026 | Work on test Supermodule 36; start of DAQ, test and DQM software development; test beam campaign and analysis |
| 2027 | ECAL supermodules removed from the CMS detector (current schedule); replacement and testing of the electronics; data quality validation |
| 2028 | Supermodules reinserted into CMS (current schedule) |
| Final phase | Spike-killer optimization, electronics integration support and commissioning |
Dates follow the current CMS schedule and may change.